User/OEM Defaults
Overview
The drive allows you to save the current parameter configuration as User/OEM Defaults. Once saved, these settings can be restored instead of the factory default parameter set, enabling faster commissioning of identical machines or OEM-specific configurations.
Before You Start
Before saving User/OEM Defaults, ensure that:
The drive configuration has been fully verified and represents the desired default setup.
Save User/OEM Defaults
To save the current drive configuration as User/OEM Defaults:
Complete drive commissioning and verify all required settings.
Set P-71 = 1.
The display will show Usr-PS while the parameter set is being stored.
Once complete, the drive returns to normal operation.
Note
Saving User/OEM Defaults overwrites any previously stored User/OEM configuration.
Restore User/OEM Defaults
To restore the saved User/OEM Defaults:
Ensure the drive is stopped.
Press and hold ▲ + ▼ + Stop buttons.
The display shows U-def.
Release the keys.
The drive loads the stored User/OEM parameter set.
Display Messages
Display | Description |
|---|---|
Usr-PS | User/OEM parameter set is being saved. |
U-def | User/OEM Defaults are being restored. |
Usr-cL | User/OEM Default parameter set is being cleared. |
Troubleshooting & FAQs
Problem | Solution |
|---|---|
Can I remove the saved User/OEM Defaults? | Yes. Set P-71 = 2 to clear the stored User/OEM parameter set. |