Power Terminal Cable Size & Torque Information
This section details the cable sizes, termination methods and tightening torque for the Elevator Core power terminals.
The power terminals refer to the: Input Supply (L1/L, L2/N L3 & Earth), Motor Output (U,V,W & Earth) and Brake Resistor/DC Bus (DC+, BR, DC-).
Cable Sizing
200 – 240 Volt (+/-10%), 1 Phase Input (50-60Hz +/- 5%) | |||||||
|---|---|---|---|---|---|---|---|
Drive Model Code | Maximum Input Supply Cables Size (L1/L, L2/N, L3, Earth) | Maximum Motor Phase & Brake Resistor Cables Size (U, V, W, Earth, DC+, BR, DC-) | Screw Type | Recommended Screw Tightening Torque | |||
Units | mm2 | AWG/ kcmil | mm2 | AWG/ kcmil | Nm | Ibf.in | |
ODL-3-220105-142SB# | 6 | 10 | 6 | 10 | M3 Phillips | 1.5 | 13.3 |
200 – 240 Volt (+/-10%), 3 Phase Input (50-60Hz +/- 5%) | |||||||
|---|---|---|---|---|---|---|---|
Drive Model Code | Maximum Input Supply Cables Size (L1/L, L2/N, L3, Earth) | Maximum Motor Phase & Brake Resistor Cables Size (U, V, W, Earth, DC+, BR, DC-) | Screw Type | Recommended Screw Tightening Torque | |||
Units | mm2 | AWG/ kcmil | mm2 | AWG/ kcmil | Nm | Ibf.in | |
ODL-3-220180-342SB# | 6 | 10 | 6 | 10 | M3 Phillips | 1.5 | 13.3 |
ODL-3-220240-342SB# | 6 | 10 | 6 | 10 | M3 Phillips | 1.5 | 13.3 |
ODL-3-320300-342SB# | 16 | 6 | 16 | 6 | M4 Phillips | 1.5 | 13.3 |
380 – 480 Volt (+/-10%), 3 Phase Input (50-60Hz +/- 5%) | |||||||
|---|---|---|---|---|---|---|---|
Drive Model Code | Maximum Input Supply Cables Size (L1/L, L2/N, L3, Earth) | Maximum Motor Phase & Brake Resistor Cables Size (U, V, W, Earth, DC+, BR, DC-) | Screw Type | Recommended Screw Tightening Torque | |||
Units | mm2 | AWG/ kcmil | mm2 | AWG/ kcmil | Nm | Ibf.in | |
ODL-3-240095-342SB# | 6 | 10 | 6 | 10 | M3 Phillips | 1.5 | 13.3 |
ODL-3-240140-342SB# | 6 | 10 | 6 | 10 | M3 Phillips | 1.5 | 13.3 |
ODL-3-340180-342SB# | 16 | 6 | 16 | 6 | M4 Phillips | 1.5 | 13.3 |
ODL-3-340240-342SB# | 16 | 6 | 16 | 6 | M4 Phillips | 1.5 | 13.3 |
ODL-3-340300-342SB# | 16 | 6 | 16 | 6 | M4 Phillips | 1.5 | 13.3 |
The Elevator Core drive is designed to accept terminals from the following termination methods for all Input supply, Motor and Brake Resistor terminals:
Bare Conductor
Bootlace Ferrule
Drive Frame Size | Maximum Cable Stripped Length (mm) |
|---|---|
2 | 8 |
3 | 13 |
4 | 18 |