Warning message

Description

Corrective Action/Further information

OvLd

Drive is in Overload condition - currently delivering > 100% of P4-03.

Increase acceleration ramp (P8-03).

Reduce the load, check the load mechanically to ensure it is free, and that no jams, blockages or other mechanical faults exist.

If operating a Gearless motor check the encoder offset is correct and try repeating the measurement to confirm consistent values are being measured (P4-08=3).

Ot-br

Brake Resistor Overtemperature warning

Based on brake resistor over temperature feedback via drive terminals.

Set using P3-07.

Ot-Mm

Motor Overtemperature warning

Based on motor thermistor over temperature feedback via drive terminals.

Ot-Dr

Drive Overtemperature warning

Reduce drive temperature by providing sufficient cooling to the drive.

Check drive heatsink fan is working with 5 button press.

noACin

Mains Loss

Check AC Supply is connected.

Check AC is connected to the drive input terminals and not the drive output terminals U,V,W.

SEr

Service Required

The time programmed in parameter P11-17 (Service time interval) has elapsed.

tr-lt

Travel Limit Reached

Travel direction Change counter (Rope Wear Counter) as per set in parameter P10-05 has been reached.