Skip to main content

Elevator Core Reference Guide

Group 9.8 Comfort Optimisation - Motor Pre-torque adjustment

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P9-36

Motor Pre-Torque in Clockwise Direction

%

0.0%

-100 ... 100%

RW

Y

1 = 0.1 %

2

23A8h

0

936

P9-37

Motor Pre-Torque in Counter-Clockwise Direction

%

0.0%

-100 ... 100%

RW

Y

1 = 0.1 %

2

23A9h

0

937

P9-38

Speed Error Dead Band

%

2.0%

0.0 ... 100.0%

RW

Y

1 = 0.1 %

2

23AAh

0

938

% of motor rated current. Used to provide torque immediately as the drive starts. Used to stop rollback.

% of motor rated current. Used to provide torque immediately as the drive starts. Used to stop rollback.

When the speed error value is below this parameter the speed gains are reduced.