Group 11.4 Display Scaling Source

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P11-11

Display Scaling Factor

N/A

0.000

-30.000 ... 30.000

RW

Y

1 = 0.001

2

2457h

0

1111

P11-12

Display Scaling Source

N/A

2

0 ... 6

RW

Y

N/A

1

2458h

0

1112

If P11-11 is set >0, the variable selected in P11-12 is multiplied by the factor entered in P11-11, and displayed whilst the drive is running with a ā€˜c’ to indicate the customer scaled units.

P11-11 & P11-12 allow the user to program the drive to display an alternative output unit scaled from an existing parameter, e.g. to display speed in meters per second based on the output frequency.

Note

This function is disabled if P11-11 is set to 0.

Source to be multiplied by P11-11

Setting

Scaling Source

0

Motor Speed

1

Motor Current

2

Speed Error (As defined by parameter P0-16 (Speed Following Error)

3

Encoder Offset (Real-Time) (As per P0-20)

4

Elevator Sequence Segment (As per P0-35)

5

Rollback Error Count (As defined by P0-17)

6

P0-75 (signed with one decimal place) – Internal use only