Group 9 Comfort Optimisation - Speed Loop Gains

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P9-23

Speed Loop Proportional Gain at Start

%

50.0%

0.0 ... 400.0%

RW

Y

1 = 0.1 %

2

239Bh

0

923

P9-24

Speed Loop Integral Gain at Start

ms

50ms

0 ... 1000ms

RW

Y

1 = 1 ms

2

239Ch

0

924

P9-25

Speed Loop Gain Transition Speed During Acceleration

Hz / rpm / ft/s / m/s

0.00Hz

0.0 ... P8-01

RW

Y

1 = 0.01Hz

2

239Dh

0

925

P9-26

Speed Loop Gain Transition Bandwidth During Acceleration

Hz / rpm / ft/s / m/s

0.00Hz

0.0 ... P8-01

RW

Y

1 = 0.01Hz

2

239Eh

0

926

P9-27

Speed Loop Proportional Gain During Run

%

50.0%

0 ... 400.0%

RW

Y

1 = 0.1 %

2

239Fh

0

927

P9-28

Speed Loop Integral Gain During Run

ms

50ms

0 ... 1000ms

RW

Y

1 = 1 ms

2

23A0h

0

928

P9-29

Speed Loop Differential Gain During Run

%

0.0%

0.0 ... 400.0%

RW

Y

1 = 0.1 %

2

23A1h

0

929

P9-30

Speed Loop Proportional Gain During Deceleration

%

50.0%

0 ... 400.0%

RW

Y

1 = 0.1 %

2

23A2h

0

930

P9-31

Speed Loop Integral Gain During Deceleration

ms

50ms

0 ... 1000ms

RW

Y

1 = 1 ms

2

23A3h

0

931

P9-32

Speed Loop Gain Transition Speed During Deceleration

Hz / rpm / ft/s / m/s

0.00Hz

0.0 ... P8-01

RW

Y

1 = 0.01Hz

2

23A4h

0

932

P9-33

Speed Loop Gain Transition Bandwidth During Deceleration

Hz / rpm / ft/s / m/s

0.00Hz

0.0 ... P8-01

RW

Y

1 = 0.01Hz

2

23A5h

0

933

P9-34

Speed Loop Proportional Gain at Zero Speed

%

50.0%

0 ... 400.0%

RW

Y

1 = 0.1 %

2

23A6h

0

934

P9-35

Speed Loop Integral Gain at Zero Speed

ms

50ms

0 ... 1000ms

RW

Y

1 = 1 ms

2

23A7h

0

935