Group 10.3 Extended Functions - Rope Wear Counter
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-03 | Travel Direction Change Counter (non-resettable) | N/A | 0 | 0 ... 4294967295 | RO | N | N/A | 4 | 23EBh | 0 | 1003 |
P10-04 | Travel Direction Change Counter | N/A | 0 | 0 ... 4294967295 | RO | N | N/A | 4 | 23ECh | 0 | 1004 |
P10-05 | Travel Direction Change Counter limit | N/A | 0 | 0 ... 1013995 | RW | Y | N/A | 4 | 23EDh | 0 | 1005 |
Counts up by 1 every time there is a change in travel direction. This parameter is not reset with a factory/user default.
Counts up by 1 every time there is a change in travel direction. This parameter can be reset with a factory/user default of the drive
When the value entered in this parameter has been reached a warning message (tr-Lt) is shown on the drive display and a digital output or Relay will come on (If output source is set for 18 - Travel Limit Counter Reached.