Skip to main content

Elevator Core Reference Guide

Group 10.3 Extended Functions - Rope Wear Counter

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-03

Travel Direction Change Counter (non-resettable)

N/A

0

0 ... 4294967295

RO

N

N/A

4

23EBh

0

1003

P10-04

Travel Direction Change Counter

N/A

0

0 ... 4294967295

RO

N

N/A

4

23ECh

0

1004

P10-05

Travel Direction Change Counter limit

N/A

0

0 ... 1013995

RW

Y

N/A

4

23EDh

0

1005

Counts up by 1 every time there is a change in travel direction. This parameter is not reset with a factory/user default.

Counts up by 1 every time there is a change in travel direction. This parameter can be reset with a factory/user default of the drive

When the value entered in this parameter has been reached a warning message (tr-Lt) is shown on the drive display and a digital output or Relay will come on (If output source is set for 18 - Travel Limit Counter Reached.