Skip to main content

Elevator Core Reference Guide

Group 11.3 Drive Configuration - Read Only Parameters

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P11-30

Drive Type Code

N/A

Drive Dependent

Drive Dependent

RO

N

N/A

2

246Ah

0

1130

P11-31

Drive Branding Identifier

N/A

Drive Dependent

0 ... 65535

RO

N

N/A

2

246Bh

0

1131

P11-37

Drive rated current

Amps

Drive Dependent

N/A

RO

N

1 = 0.1A

2

2471h

0

1137

P11-38

Drive rated voltage

Volts

Drive Dependent

N/A

RO

N

N/A

2

2472h

0

1138

P11-39

Drive rated power (kW)

kW

Drive Dependent

N/A

RO

N

1 = 0.1 kW

2

2473h

0

1139

P11-40

Drive rated power (HP)

HP

Drive Dependent

N/A

RO

N

1 = 0.1 HP

2

2474h

0

1140

P11-41

Number of input phases

N/A

Drive Dependent

1 ... 3

RO

N

N/A

1

2475h

0

1141

P11-42

Drive frame size

N/A

Drive Dependent

1 ... 5

RO

N

N/A

1

2476h

0

1142

P11-43

Duty Rating

N/A

Drive Dependent

0 ... 1

RO

N

N/A

1

2477h

0

1143

P11-44

IP Rating

N/A

Drive Dependent

0 ... 66

RO

N

N/A

1

2478h

0

1144