Group 7 Rescue Operation - Parameter List

Group 7.1 Rescue Operation - Rescue Mode Setup

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-01

Rescue Supply type

N/A

0: 230V UPS

0: 230V UPS

1: 400V UPS

2: Battery Operation

RW

N

N/A

1

22BDh

0

701

P7-02

Rescue Operation Function

N/A

0: Basic Rescue Mode

0: Basic Rescue Mode

1: Light Load Detection

2: UPS Easiest Direction based on Load Measurement

3: Energy Optimized

RW

N

N/A

1

22BEh

0

702

Group 7.2 Rescue Operation - Basic Rescue Mode

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-03

Rescue Mode Speed

Hz / rpm / ft/s / m/s

5.00Hz

P8-02 ... P8-01

RW

Y *Does not take effect until next travel

1 = 0.1 Hz

2

22BFh

0

703

Group 7.3 Rescue Operation - UPS Protection Function

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-04

UPS Rating

kW

0.0

0.0 ... 65535

RW

Y

1 = 0.1 kW

2

22C0h

0

704

P7-05

Rescue Mode Current Limit

%

100.0%

0.0 ... 200.0%

RW

Y

1 = 0.1%

2

22C1h

0

705

Group 7.4 Speed Loop Gains

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-06

Rescue Mode Proportional Speed Loop Gain

%

10.0%

0.0 ... 400.0%

RW

Y

1 = 0.1%

2

22C2h

0

706

P7-07

Rescue Mode Integral Speed Loop Gain

ms

50ms

0 ... 1000ms

RW

Y

1 = 0.1ms

2

22C3h

0

707

Group 7.4 Rescue Operation - Light Load Detection

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-08

Light Load Detection Measurement time

sec

1.0s

0.0 ... 10.0s

RW

Y

1 = 0.1s

1

22C4h

0

708

P7-09

Light Load Detection Speed

Hz / rpm / ft/s / m/s

5.00

P8-02 ... P8-01

RW

Y *Does not take effect until next travel

1 = 0.01Hz

1 = 1rpm

2

22C5h

0

709

Group 7.5 Rescue Operation - UPS Easiest Direction based on Load Measurement

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-10

Load Measurement extended time

sec

0.0s

0.0 ... 10.0s

RW

Y

1 = 0.1s

1

22C6h

0

710

P7-11

Light Load Detection Results

N/A

0: Light direction is clockwise

0: Light direction is clockwise

1: Light direction is Anti-clockwise

2: Balanced

RO

N

N/A

1

22C7h

0

711

Group 7.6 Rescue Operation - Energy Optimisation

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-12

Energy Saving Rescue Unbalancing Max speed

Hz / rpm / ft/s / m/s

5.00 Hz

P8-02 ... P8-01

RW

Y

1 = 0.01Hz

2

22C8h

0

712

P7-13

Energy Saving Rescue Minimum Speed

Hz / rpm / ft/s / m/s

5.00 Hz

P8-02 ... P8-01

RW

Y

1 = 0.01Hz

2

22C9h

0

713

P7-14

Energy Saving Rescue Minimum Speed Time

sec

0.0s

0.0 ...10.0s

RW

Y

1 = 0.1s

1

22CAh

0

714

Group 7.8 - Rescue Mode Read Only

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-15

Rescue mode active

N/A

0: Mains Supply

0: Mains Supply

1: Rescue Supply

RO

N

N/A

1

22CBh

0

715

Group 7.9 - Rescue Mode UPS Limit

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P7-16

UPS overload time limit

sec

2.0s

0.0 ... 10.0s

RW

N

1 = 0.1s

1

22CCh

0

716