Skip to main content

Elevator Core Reference Guide

Group 12 Address - Parameter list

Group 12.1 User I/O Configuration - Input Function Select

Parameter Number

Parameter Name

Units

Default

Available Settings

Drop Down Options

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P12-01

DI1 input Function select

N/A

1: Run Forward

0 ... 29

0: No Function

1: Run Forward

2: Run Reverse

3: Levelling Speed

4: High Speed

5: High Speed 5

6: Inspection Speed

7: Fault Reset

8: Rescue Mode

9: E-Trip Mode 1

10: Preset with override High Speed 

11: Preset with override Inspection Speed

12: Preset with override Intermediate Speed

13: E-Trip Mode 2 

14: Preset Bit 0 (2)

15: Preset Bit 1 (2) 

16: Preset Bit 2 (2)

17: Speed Reference 

18: Torque Sensor 

19: Spare

20: Spare

21: Drive Enable

22: E-Trip Mode 3

23: Brake Release Monitor Input 1

24: Brake Release Monitor Input 2 

25: Analog mode 

26: Direction (0 – Fwd, 1 - Rev)

27: Preset Bit 0 With Active (3) 

28: Preset Bit 1 With Active (3)

29: Preset Bit 2 With Active (3)

RW

Y

N/A

1

24B1

0

1201

P12-02

DI2 input Function select

N/A

2: Run Reverse

0 ... 29

RW

Y

N/A

1

24B2

0

1202

P12-03

DI3 input Function select

N/A

3: Levelling Speed

0 ... 29

RW

Y

N/A

1

24B3

0

1203

P12-04

DI4 input Function select

N/A

4: High Speed

0 ... 29

RW

Y

N/A

1

24B4

0

1204

P12-05

DI5 input Function select

N/A

5: High Speed 5

0 ... 29

RW

Y

N/A

1

24B5

0

1205

P12-06

DI6 input Function select

N/A

6: Inspection Speed

0 ... 29

RW

Y

N/A

1

24B6

0

1206

P12-07

DI7 input Function select

N/A

7: Fault Reset

0 ... 29

RW

Y

N/A

1

24B7

0

1207

P12-08

DI8 input Function select

N/A

8: Rescue Mode

0 ... 29

RW

Y

N/A

1

24B8

0

1208

P12-09

Daux1 input Function select

N/A

0: No Function

0 ... 29

RW

Y

N/A

1

24B9

0

1209

P12-10

Daux2 input Function select

N/A

0: No Function

0 ... 29

RW

Y

N/A

1

24BA

0

1210

Parameter References

Group 12.2 User I/O Configuration - Parameter References

Parameter Number

Parameter Name

Units

Default

Available Settings

Drop Down Options

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P12-11

Speed reference source

N/A

0

0 ... 5

N/A

RO

Y

N/A

1

24BB

0

1211

P12-12

Reference active

N/A

0

0 ... 1

N/A

RO

Y

N/A

1

24BC

0

1212

P12-13

User pre-ramp reference 

Hz

0.00

-P8-01 to P8-01

N/A

RO

Y

1 = 0.1 Hz

2

24BD

0

1213