Group 10 Extended Functions - Parameter List
Group 10.1 Extended Functions - Short Floor Operation
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-01 | Enable Short Floor Operation | N/A | 0: Disabled | 0: Disabled 1: Enabled | RW | N | N/A | 1 | 23E9h | 0 | 1001 |
Group 10.2 Extended Functions - Early Door Opening
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-02 | Early Door Opening Speed Threshold | % | 0.0% | 0.0 ... 100.0% | RW | Y | 1 = 0.1 % | 2 | 23EAh | 0 | 1002 |
Group 10.3 Extended Functions - Rope Wear Counter
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-03 | Travel Direction Change Counter (non-resettable) | N/A | 0 | 0 ... 4294967295 | RO | N | N/A | 4 | 23EBh | 0 | 1003 |
P10-04 | Travel Direction Change Counter | N/A | 0 | 0 ... 4294967295 | RO | N | N/A | 4 | 23ECh | 0 | 1004 |
P10-05 | Travel Direction Change Counter limit | N/A | 0 | 0 ... 1013995 | RW | Y | N/A | 4 | 23EDh | 0 | 1005 |
Group 10.4 Extended Functions - Travel Counter
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-06 | Reset motor direction change counter | N/A | 0: Disabled | 0: Disabled 1: Reset | RW | Y | N/A | 1 | 23EEh | 0 | 1006 |
P10-07 | Number of travels | N/A | 0 | 0 ... 4294967295 | RO | N | N/A | 4 | 23EFh | 0 | 1007 |
Group 10.5 Extended Functions - Motor Connected Check
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-08 | Motor Connected Check | % | 5.0% | 0.0 ... 100.0% | RW | N | 1 = 0.1 % | 2 | 23F0h | 0 | 1008 |
Group 10.6 Extended Functions - Anti-Stall
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-09 | Anti-Stall Enable | N/A | 0: Disabled | 0: Disabled 1: Enabled | RW | N | N/A | 1 | 23F1h | 0 | 1009 |
P10-10 | Anti-Stall Limit | % | 100.0% | 100.0 ... 250.0% | RW | N | 1 = 0.1 % | 2 | 23F2h | 0 | 1010 |
P10-11 | Anti-Stall Hysteresis | % | 10.0% | 0.0 ... 50.0% | RW | N | 1 = 0.1 % | 2 | 23F3h | 0 | 1011 |
Group 10.7 Extended Functions - Motor Overspeed governor Test
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-12 | Overspeed Governor test speed | % | 0.0% | 0.0 ... 125% | RW | - | - | 2 | 23F4h | 0 | 1012 |
Group 10.8 Extended Functions - Travel Counter Read Only
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-13 | Travel Direction Change Counter Limit Reached | N/A | 0 | 0 ... 1 | RO | N | N/A | 1 | 23F5h | 0 | 1013 |