Skip to main content

Elevator Core Reference Guide

Group 10 Extended Functions - Parameter List

Group 10.1 Extended Functions - Short Floor Operation

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-01

Enable Short Floor Operation

N/A

0: Disabled

0: Disabled

1: Enabled

RW

N

N/A

1

23E9h

0

1001

Group 10.2 Extended Functions - Early Door Opening

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-02

Early Door Opening Speed Threshold

%

0.0%

0.0 ... 100.0%

RW

Y

1 = 0.1 %

2

23EAh

0

1002

Group 10.3 Extended Functions - Rope Wear Counter

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-03

Travel Direction Change Counter (non-resettable)

N/A

0

0 ... 4294967295

RO

N

N/A

4

23EBh

0

1003

P10-04

Travel Direction Change Counter

N/A

0

0 ... 4294967295

RO

N

N/A

4

23ECh

0

1004

P10-05

Travel Direction Change Counter limit

N/A

0

0 ... 1013995

RW

Y

N/A

4

23EDh

0

1005

Group 10.4 Extended Functions - Travel Counter

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-06

Reset motor direction change counter

N/A

0: Disabled

0: Disabled

1: Reset

RW

Y

N/A

1

23EEh

0

1006

P10-07

Number of travels

N/A

0

0 ... 4294967295

RO

N

N/A

4

23EFh

0

1007

Group 10.5 Extended Functions - Motor Connected Check

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-08

Motor Connected Check

%

5.0%

0.0 ... 100.0%

RW

N

1 = 0.1 %

2

23F0h

0

1008

Group 10.6 Extended Functions - Anti-Stall

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-09

Anti-Stall Enable

N/A

0: Disabled

0: Disabled

1: Enabled

RW

N

N/A

1

23F1h

0

1009

P10-10

Anti-Stall Limit

%

100.0%

100.0 ... 250.0%

RW

N

1 = 0.1 %

2

23F2h

0

1010

P10-11

Anti-Stall Hysteresis

%

10.0%

0.0 ... 50.0%

RW

N

1 = 0.1 %

2

23F3h

0

1011

Group 10.7 Extended Functions - Motor Overspeed governor Test

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-12

Overspeed Governor test speed

%

0.0%

0.0 ... 125%

RW

-

-

2

23F4h

0

1012

Group 10.8 Extended Functions - Travel Counter Read Only

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P10-13

Travel Direction Change Counter Limit Reached

N/A

0

0 ... 1

RO

N

N/A

1

23F5h

0

1013