Skip to main content

Elevator Core Reference Guide

Group 11.1 Drive Configuration - On-board Back-up of user parameter settings

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P11-01

Save User Defaults

N/A

0: No Action

0 ... 2

RW

N

N/A

1

244Dh

0

1101

The drive can store a backup of the user parameter settings, this is useful in the event of someone inadvertently adjusting the drive operational parameters and allows for the parameter settings to be returned exactly as per the original installation.

Once the drive has been programmed for the application, setting parameter P11-01 to a 1 will save the drive parameters as user default parameters.

Settings

Function

0

No Action

1

Saves the current parameter settings as "User default parameters".

When the User carries out a 3-button default parameter command (UP, DOWN and STOP), the parameters saved when P11-01 was last set to 1 will be restored.

The display will show the message USr-PS to indicate the values have been saved.

2

Clears user parameters. A 3-button default with no user default parameters saved will restore factory defaults.

The display will show the message USr-cL to indicate factory defaults have now been loaded.