Elevator Core Reference Guide

Group 2.2 Communications - CANopen

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P2-07

CANopen Address

N/A

1

1 ... 127

RW

N

N/A

1

20CFh

0

207

P2-08

CANopen Baud Rate

N/A

2: 500kbps

0: 125kbps

1: 250kbps

2: 500kbps

3: 1Mbps

RW

N

N/A

1

20D0h

0

208

P2-09

CANopen Comms Loss Reaction

N/A

2: Ramp to Stop Only (No Trip)

0: Trip

1: Ramp to Stop then Trip

2: Ramp to Stop Only (No Trip)

3: Run at Inspection Speed (P8-09)

 RW

Y

N/A 

1

20D1h

0

209

Sets the drive address when communicating over CANopen via the RJ45 port on the drive.

Sets the baud rate when CANopen communications is being used.

Controls the behaviour of the drive following a loss of communications with CANopen when using Heartbeat or Node Guarding.

Setting

Reaction

0

Immediate trip

1

Ramp to stop then trip

2

Ramp to stop only (No Trip)

3

Run at Inspection Speed (P8-08)