Group 7.6 Rescue Operation - Energy Optimisation
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P7-12 | Energy Saving Rescue Unbalancing Max speed | Hz / rpm / ft/s / m/s | 5.00 Hz | P8-02 ... P8-01 | RW | Y | 1 = 0.01Hz | 2 | 22C8h | 0 | 712 |
P7-13 | Energy Saving Rescue Minimum Speed | Hz / rpm / ft/s / m/s | 5.00 Hz | P8-02 ... P8-01 | RW | Y | 1 = 0.01Hz | 2 | 22C9h | 0 | 713 |
P7-14 | Energy Saving Rescue Minimum Speed Time | sec | 0.0s | 0.0 ...10.0s | RW | Y | 1 = 0.1s | 1 | 22CAh | 0 | 714 |
This is the maximum allowable speed when the drive is operating in rescue mode and with P7-02 = 3, when this value is reached the drive will command the motor brake to apply.
This is the minimum speed that must be achieved when Energy saving mode is active, further this speed must be achieved within the time set in P7-14, otherwise the drive will apply the brake and automatically carry out the Light Load Detection test (as per P7-02=1) on Geared motors or use direction from controller (P7-02 = 0) on gearless motors.
This parameter is used in conjunction with P7-13, when Energy Saving mode (P7-02 = 3) is active the speed must be at least the value in P7-13 within the time set in P7-14.