Skip to main content

Elevator Core Reference Guide

Battery Supply Requirements

When operating in battery mode the drive uses a different set of conditions for operation voltage thresholds. These are detailed in the table below.

Rescue Power Supply Type

Required Connections

Nominal Rating

Minimum Voltage

Maximum Voltage

Current Requirements

Battery Power Supply

High Power connections to terminals +DC and -DC

-

32Vdc (<24Vdc will result in an undervoltage trip)

200-240V drives = 240Vdc

380-480V drives = 450Vdc

Motor Rated current (P4-03) and considering overload, typically no greater than 200%

Control +24V connection to terminals 0V and +24V

24V

20V

26V

2.2A (60W)