Battery Supply Requirements
When operating in battery mode the drive uses a different set of conditions for operation voltage thresholds. These are detailed in the table below.
Rescue Power Supply Type | Required Connections | Nominal Rating | Minimum Voltage | Maximum Voltage | Current Requirements |
---|---|---|---|---|---|
Battery Power Supply | High Power connections to terminals +DC and -DC | - | 32Vdc (<24Vdc will result in an undervoltage trip) | 200-240V drives = 240Vdc 380-480V drives = 450Vdc | Motor Rated current (P4-03) and considering overload, typically no greater than 200% |
Control +24V connection to terminals 0V and +24V | 24V | 20V | 26V | 2.2A (60W) |