Group 10.2 Extended Functions - Early Door Opening
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-02 | Early Door Opening Speed Threshold | % | 0.0% | 0.0 ... 100.0% | RW | Y | 1 = 0.1 % | 2 | 23EAh | 0 | 1002 |
Any of the drives digital outputs or relays can be set to give an output when the door zone speed condition has been met (setting 16), example of using Digital output 3 shown above.
The output will only come on during deceleration approaching the floor.
The Early Door opening function is used to provide the elevator controller with a signal (From a digital output) at a set speed to open the elevator doors prior to reaching the exact floor level (saving time at stop to open the doors).