Skip to main content

Elevator Core Reference Guide

Group 9.2 Comfort Optimisation - Smooth Start Function

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P9-08

Smooth Start Time

sec

0.0s

0.0 ... 5.0s

RW

Y

1 = 0.1 s

1

238Ch

0

908

P9-09

Smooth Start Speed

Hz / rpm / ft/s / m/s

0.00Hz

0.00 ... P8-01

RW

Y

1 = 0.01Hz

2

238Dh

0

909

P9-10

Smooth Start Ramp Time

sec

0.50s

0.00 ... 600.00s

RW

Y

1 = 0.01 s

2

238Eh

0

910

Sets the time that the Smooth Start Function is active for once the drive reaches the speed set in P9-09.

Must have a value > 0 for Smooth Start to be active.

Sets the target speed for the drive during the Smooth Start Function.

Must have a value > 0 for Smooth Start to be active.

Sets the ramp time to reach the target speed set in P9-09.