Skip to main content

Elevator Core Reference Guide

Group 3.2 System - Motor Contactor Monitoring

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P3-02

Motor Contactor Monitoring Terminal Enable

N/A

0: Off

0: Off

1: Enabled

RW

Y

N/A

1

212Eh

0

302

P3-03

Total Number of Motor Contactor Monitoring Errors

N/A

0

0 ... 65535

RO

N/A

N/A

2

212Fh

0

303

Sets the Motor Contactor Monitoring function to enabled or disabled.

Setting

Function

0

Off - Motor Contactor Monitoring disabled

1

Enabled - Motor Contactor Monitoring enabled

Applicable Macros (P1-02) for Motor Contactor Monitoring Function:

  • Through Digital Input 5 when P1-02 Macro = 2 or 4

  • Through any Digital Input as selected in P12-32 when P1-02 = 0 (free off digital Input for user defined settings)

This value increments by 1 each time there is cF-Err error.

The value can only be reset by loading factory/user defaults.