Group 3.2 System - Motor Contactor Monitoring
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P3-02 | Motor Contactor Monitoring Terminal Enable | N/A | 0: Off | 0: Off 1: Enabled | RW | Y | N/A | 1 | 212Eh | 0 | 302 |
P3-03 | Total Number of Motor Contactor Monitoring Errors | N/A | 0 | 0 ... 65535 | RO | N/A | N/A | 2 | 212Fh | 0 | 303 |
Sets the Motor Contactor Monitoring function to enabled or disabled.
Setting | Function |
---|---|
0 | Off - Motor Contactor Monitoring disabled |
1 | Enabled - Motor Contactor Monitoring enabled |
Applicable Macros (P1-02) for Motor Contactor Monitoring Function:
This value increments by 1 each time there is cF-Err error.
The value can only be reset by loading factory/user defaults.