Skip to main content

Elevator Core Reference Guide

Elevator Core CANopen PDO Default Mapping

Table 14. Default PDO mapping on power up

Objects No.

Mapped Object

Length

Mapped Function

Transmission Type

RX PDO1

1

2000h

Unsigned 16

Control Word

254 Valid immediately

RX PDO1

2

2001h

Integer 16

Speed reference

254 Valid immediately

RX PDO1

3

2003h

Unsigned 16

Reserved

254 Valid immediately

RX PDO1

4

0006h

Unsigned 16

Reserved

254 Valid immediately

TX PDO1

1

200Ah

Unsigned 16

Drive status register

254 Send after receiving RX PDO1

TX PDO1

2

200Bh

Integer 16

Motor speed Hz

254 Send after receiving RX PDO1

TX PDO1

3

200Dh

Unsigned 16

Motor current

254 Send after receiving RX PDO1

TX PDO1

4

2010h

Integer 16

Drive temperature

254 Send after receiving RX PDO1

RX PDO2

1

0006h

Unsigned 16

Dummy

254

RX PDO2

2

0006h

Unsigned 16

Dummy

254

RX PDO2

3

0006h

Unsigned 16

Dummy

254

RX PDO2

4

0006h

Unsigned 16

Dummy

254

TX PDO2

1

2011h

Unsigned 16

DC bus voltage

254

TX PDO2

2

2012h

Unsigned 16

Digital input status

254

TX PDO2

3

2013h

Integer 16

Analog input 1 (%)

254

TX PDO2

4

2014h

Integer 16

Analog input 2 (%)

254