Group 11.2 Drive Configuration - Parameter access loc
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P11-02 | Extended Group Access Code | N/A | 0 | 0 ... 9999 | RW | Y | N/A | 2 | 244Eh | 0 | 1102 |
P11-03 | Parameter Access Lock | N/A | 0: Unlocked | 0: Unlocked 1: Locked | RW | Y | N/A | 1 | 244Fh | 0 | 1103 |
P11-04 | Level 2 Access Definition | N/A | 101 | 0 ... 9999 | RW | Y | N/A | 2 | 2450h | 0 | 1104 |
The value entered in parameter P11-02 determines which parameter groups are accessible by the user by Default if:
P11-02 = 0 = Level 1 parameter groups can be accessed.
P11-02 = 101 = Level 2 parameter groups can be accessed.
Level 1 access includes groups 0 through to group 11.
Level 2 access includes groups 0 through to group 12.
The code for Level 2 can be changed by the user by setting the desired value into parameter P11-04.
Setting | Function |
---|---|
0 | All parameters can be accessed and changed |
1 | Parameters are made read only (apart from P11-02 and P11-04) |
Enter your chosen access code here (> 0) which once set must be entered in P11-02 to access parameter Group 2.
Once set this parameter will become hidden until the same value is entered into P11-02.
NOTE: When the menu access code (P11-04) is changed then it must be retained in a safe location for further reference to allow further configuration or service. Forgotten access codes can be cleared by returning the drive back to default settings. A default is performed by pressing STOP, UP and DOWN buttons simultaneously for more than 2 seconds. This will clear all drive parameters, including the security codes back to default values.