Group 4.5 - Stopping

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P4-16

Flux Braking Current Level

%

20.0%

0.0 ... 200.0%

RW

Y

1 = 0.1%

2

21A0h

0

416

P4-17

Torque Reduction time during stopping

sec

1.0s

0.0 ... 10.0s

RW

Y

1 = 0.1 s

1

21A1h

0

417

Additional flux during braking/regen

Setting 0 means function is disabled. This parameter helps in reducing the noise in the lift car when the motor brake is applied due to the immediate removal of current. Increasing this value reduces audible noise, setting too high can result in reduced torque and rollback during stopping.

This parameter has no effect when operating in an IM control mode (P4-01 = 0 or 1) and the torque reduction time is fixed at 100ms.