Group 3 System - Parameter List
Group 3 System - System Mechanical Data/Linear Units operation
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P3-01 | Motor Contactor Closing Time | sec | 0.2s | 0.0 ... 5.0s | RW | Y | 1 = 0.1 seconds | 1 | 212Dh | 0 | 301 |
Group 3.2 System - Motor Contactor Monitoring
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P3-02 | Motor Contactor Monitoring Terminal Enable | N/A | 0: Off | 0: Off 1: Enabled | RW | Y | N/A | 1 | 212Eh | 0 | 302 |
P3-03 | Total Number of Motor Contactor Monitoring Errors | N/A | 0 | 0 ... 65535 | RO | N/A | N/A | 2 | 212Fh | 0 | 303 |
Group 3.3 System - Brake Resistor Protection
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P3-04 | Brake Resistor Resistance | ohms | Rating Dependent | 0 ... 60000 ohms | RW | Y | N/A | 2 | 2130h | 0 | 304 |
P3-05 | Brake Resistor Power | kW | 0.0kW | 0.0 ... 6000.0 kW | RW | Y | 1 = 1 W | 2 | 2131h | 0 | 305 |
P3-06 | Brake Resistor Temperature Monitor Enable | N/A | 0: Disabled | 0: Disabled 1: Enabled | RW | Y | N/A | 1 | 2132h | 0 | 306 |
P3-07 | Brake Resistor Temperature Monitoring trip reaction | N/A | 0 : Normal Stop, Trip After stopping | 0: Normal Stop, Trip After stopping 1 : Immediate Trip, Apply motor Brake 2: Warning Only No Trip | RW | Y | N/A | 1 | 2133h | 0 | 307 |
Group 3.4 System - System Mechanical Data/Linear Units operation
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P3-08 | Sheave Diameter | N/A | 0.0 | 0.0 ... 2000.0 | RW | Y | 1 = 0.1 | 2 | 2134h | 0 | 308 |
P3-09 | Roping Ratio | N/A | 1: 1:1 | 1: 1:1 2: 2:1 3: 3:1 4: 4:1 | RW | Y | N/A | 1 | 2135h | 0 | 309 |
P3-10 | Gear Ratio | N/A | 1.0 | 1.0 ... 100.0 | RW | Y | 10 = 1.0 | 2 | 2136h | 0 | 310 |
P3-12 | System Inertia Constant | N/A | 10 | 0 ... 100 | RW | Y | N/A | 1 | 2138h | 0 | 312 |