Skip to main content

Elevator Core Reference Guide

Group 2.3 Communications - USB-C

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P2-10

PC/App Communications Loss Timeout

sec

2.0s

0.0 ... 5.0s

RW

N

1 = 0.1s

1

20D2h

0

210

P2-11

PC/App Communications Loss Action

N/A

0: Trip

0: Trip

1: Ramp to Stop then Trip

2: Ramp to Stop Only (No Trip)

3: Run at Inspection Speed (P8-09)

RW

N

N/A

1

20D3h

0

211

P2-13

USB Port Enable

N/A

1: Enabled

0: Disabled

1: Enabled

RW

Y

N/A

1

20D5h

0

213

Sets the timeframe for a PC/App message to be sent to the drive before tripping.

Controls the behaviour of the drive following a loss of communications from either PC/Mobile App.

Setting

Drive Display

Reaction

0

triP

Immediate trip

1

r-triP

Ramp to stop then trip

2

StoP

Ramp to stop only (No Trip)

3

InSPct

Run at Inspection Speed (P8-08)

Determines whether the USB port on the drive is enabled or not.

Setting

Function

0

Disabled - Messages can not be transferred via USB to the drive.

1

Enabled - Messages can be transferred via USB to the drive.

If the USB port is disabled then the drive will show the message USB-P on the drive display, indicating that the USB port is disabled.