Group 6.2 - Encoder Filter Settings

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P6-06

Encoder Feedback Filter at Start

ms

4ms

1 ... 20ms

RW

Y

1 = 1 ms

1

225Dh

0

606

P6-07

Encoder Feedback Filter Whilst Running

ms

4ms

1 ... 20ms

RW

Y

1 = 1 ms

1

225Eh

0

607

P6-08

Encoder Feedback Filter at Stop

ms

4ms

1 ... 20ms

RW

Y

1 = 1 ms

1

225Fh

0

608

Helps in situations where there is noise on the Incremental encoder cables, and also allows for setting of higher speed loop gains.

Helps in situations where there is noise on the Incremental encoder cables, and also allows for setting of higher speed loop gains.