Group 11.6 - Service Time
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P11-16 | Resets kWh Meter | N/A | 0: Disabled | 0: Disabled 1: Reset | RW | N | N/A | 1 | 245Ch | 0 | 1116 |
P11-17 | Service time interval | hours | 0 h | 0 ... 65535 h | RW | N | 1 = 1 hour | 2 | 245Dh | 0 | 1117 |
P11-18 | Time remaining to next service | hours | 0 h | -65536 ... 65535 h | RO | N | 1 = 1 hour | 2 | 245Eh | 0 | 1118 |
P11-19 | Reset service time indicator | N/A | 0: Disabled | 0: Disabled 1: Reset | RW | Y | N/A | 1 | 245Fh | 0 | 1119 |
Setting to 1 resets the internal energy consumption kWh meter to zero (as displayed in P13-57 and P13-58).
This defines the total number of run time hours which must elapse before the Service indicator output comes on (e.g. DA1 Output 1 function select setting 14).
NOTE: To reset this value set P11-19 to 1.
Displays the number of hours remaining on the service counter before the next service is due.
A negative value shows the service overdue hours.
When this parameter is set to 1, the internal Service time interval counter (P11-17) is reset.