Group 11.6 - Service Time

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P11-16

Resets kWh Meter

N/A

0: Disabled

0: Disabled

1: Reset

RW

N

N/A

1

245Ch

0

1116

P11-17

Service time interval

hours

0 h

0 ... 65535 h

RW

N

1 = 1 hour

2

245Dh

0

1117

P11-18

Time remaining to next service

hours

0 h

-65536 ... 65535 h

RO

N

1 = 1 hour

2

245Eh

0

1118

P11-19

Reset service time indicator

N/A

0: Disabled

0: Disabled

1: Reset

RW

Y

N/A

1

245Fh

0

1119

Setting to 1 resets the internal energy consumption kWh meter to zero (as displayed in P13-57 and P13-58).

This defines the total number of run time hours which must elapse before the Service indicator output comes on (e.g. DA1 Output 1 function select setting 14).

NOTE: To reset this value set P11-19 to 1.

Displays the number of hours remaining on the service counter before the next service is due.

A negative value shows the service overdue hours.

When this parameter is set to 1, the internal Service time interval counter (P11-17) is reset.