Elevator Core Reference Guide

Group 1.9 User IO - Hysteresis

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P1-31

DA1 Threshold Upper Limit

%

100.0%

P1-32 ... 200.0 %

RW

Y

1 = 0.1%

1

2083h

0

131

P1-32

DA1 Threshold Lower Limit

%

0.0%

0.0 ... P1-31

RW

Y

1 = 0.1%

1

2084h

0

132

P1-33

DA2 Threshold Upper Limit

%

100.0%

P1-34 ... 200.0 %

RW

Y

1 = 0.1%

1

2085h

0

133

P1-34

DA2 Threshold Lower Limit

%

0.0%

0.0 ... P1-33

RW

Y

1 = 0.1%

1

2086h

0

134

P1-35

Relay 1 Threshold Upper Limit

%

100.0%

0.0 ... 200.0 %

RW

Y

1 = 0.1%

1

2087h

0

135

P1-36

Relay 1 Threshold Lower Limit

%

0.0%

0.0 ... 100.0 %

RW

Y

1 = 0.1%

1

2088h

0

136

P1-37

Digital/Relay Output Hysteresis Band

%

0.3%

0.0 ... 25.0 %

RW

Y

1 = 0.1%

1

2089h

0

137

P1-38

DO3 Threshold Upper Limit

%

100.0%

0.0 ... 200.0 %

RW

Y

1 = 0.1%

1

208Ah

0

138

P1-39

DO3 Threshold Lower Limit

%

0.0%

0.0 ... 100.0 %

RW

Y

1 = 0.1%

1

208Bh

0

139

Used in conjunction with settings 5,6,7,10 of Parameter P1-15 DA1 Digital Output 1 Function Select

Used in conjunction with settings 5,6,7,10 of Parameter P1-22 DA1 Digital Output 2 Function Select

Used in conjunction with settings 5,6,7,10 of Parameter P1-30 (Relay 1 Source Selector)

Used in conjunction with settings 5,6,7,10 of Parameter P1-30 (Relay 1 Source Selector)

This parameter works in conjunction with P1-15, P1-22, P1-28, P1-30 = 2 or 3 to set a band around the Motor at Target Speed (e.g. P1-15 = 3) or Motor at Zero speed (e.g. P1-15 = 2). When the speed is within this band, the drive is considered to be at Target speed or Zero speed. This function is used to prevent “chatter” on the relay/Digital output if the operating speed coincides with the level at which the digital / relay output changes state. e.g. if P1-30 = 3, P8-01 = 50Hz and P1-36 = 5%, the relay contacts close above 2.5Hz.

Used in conjunction with settings 5,6,7,10 of Parameter P1-28 DO3 Digital Output 3 Function Select to set the upper limit of the threshold.

Used in conjunction with settings 5,6,7,10 of Parameter P1-28 DO3 Digital Output 3 Function Select