Group 1.9 User IO - Hysteresis
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P1-31 | DA1 Threshold Upper Limit | % | 100.0% | P1-32 ... 200.0 % | RW | Y | 1 = 0.1% | 1 | 2083h | 0 | 131 |
P1-32 | DA1 Threshold Lower Limit | % | 0.0% | 0.0 ... P1-31 | RW | Y | 1 = 0.1% | 1 | 2084h | 0 | 132 |
P1-33 | DA2 Threshold Upper Limit | % | 100.0% | P1-34 ... 200.0 % | RW | Y | 1 = 0.1% | 1 | 2085h | 0 | 133 |
P1-34 | DA2 Threshold Lower Limit | % | 0.0% | 0.0 ... P1-33 | RW | Y | 1 = 0.1% | 1 | 2086h | 0 | 134 |
P1-35 | Relay 1 Threshold Upper Limit | % | 100.0% | 0.0 ... 200.0 % | RW | Y | 1 = 0.1% | 1 | 2087h | 0 | 135 |
P1-36 | Relay 1 Threshold Lower Limit | % | 0.0% | 0.0 ... 100.0 % | RW | Y | 1 = 0.1% | 1 | 2088h | 0 | 136 |
P1-37 | Digital/Relay Output Hysteresis Band | % | 0.3% | 0.0 ... 25.0 % | RW | Y | 1 = 0.1% | 1 | 2089h | 0 | 137 |
P1-38 | DO3 Threshold Upper Limit | % | 100.0% | 0.0 ... 200.0 % | RW | Y | 1 = 0.1% | 1 | 208Ah | 0 | 138 |
P1-39 | DO3 Threshold Lower Limit | % | 0.0% | 0.0 ... 100.0 % | RW | Y | 1 = 0.1% | 1 | 208Bh | 0 | 139 |
Used in conjunction with settings 5,6,7,10 of Parameter P1-15 DA1 Digital Output 1 Function Select
Used in conjunction with settings 5,6,7,10 of Parameter P1-22 DA1 Digital Output 2 Function Select
Used in conjunction with settings 5,6,7,10 of Parameter P1-30 (Relay 1 Source Selector)
Used in conjunction with settings 5,6,7,10 of Parameter P1-30 (Relay 1 Source Selector)
This parameter works in conjunction with P1-15, P1-22, P1-28, P1-30 = 2 or 3 to set a band around the Motor at Target Speed (e.g. P1-15 = 3) or Motor at Zero speed (e.g. P1-15 = 2). When the speed is within this band, the drive is considered to be at Target speed or Zero speed. This function is used to prevent “chatter” on the relay/Digital output if the operating speed coincides with the level at which the digital / relay output changes state. e.g. if P1-30 = 3, P8-01 = 50Hz and P1-36 = 5%, the relay contacts close above 2.5Hz.
Used in conjunction with settings 5,6,7,10 of Parameter P1-28 DO3 Digital Output 3 Function Select to set the upper limit of the threshold.
Used in conjunction with settings 5,6,7,10 of Parameter P1-28 DO3 Digital Output 3 Function Select