Skip to main content

Elevator Core Reference Guide

Group 4.3 Motor Setup - Using a Motor Thermistor for overload protection

Parameter Number

Parameter Name

Units

Default

Available Settings

Access

Change During Run

Scaling

Size (Bytes)

CAN Register

CAN Sub Index

Modbus Register

P4-22

Reserved

-

-

-

-

-

-

-

-

-

-

P4-23

Motor Thermistor Trip Reaction

N/A

0: Stop at Next stop command and show thermistor fault message

0 ... 2

RW

Y

N/A

1

21A7h

0

423

Used to set the trip reaction when a motor thermistor fault occurs.

Setting

Reaction

0

Stop at Next stop command and show thermistor fault message tC-tH or ty-th depending on P1-07 or P1-13 setting.

1

Trip Immediately and show thermistor fault message tC-tH or ty-th depending on P1-07 or P1-13 setting.

2

Continue running and show thermistor fault message tC-tH or ty-th depending on P1-07 or P1-13 setting.