Group 10.7 Extended Functions - Motor Overspeed governor Test
Parameter Number | Parameter Name | Units | Default | Available Settings | Access | Change During Run | Scaling | Size (Bytes) | CAN Register | CAN Sub Index | Modbus Register |
---|---|---|---|---|---|---|---|---|---|---|---|
P10-12 | Overspeed Governor test speed | % | 0.0% | 0.0 ... 125% | RW | - | - | 2 | 23F4h | 0 | 1012 |
Parameter P10-12 can be used for testing of overspeed governors, normally performed during initial installation or scheduled inspections.
Once a value of >0.0 has been entered, the next run command from the controller to the drive will result in the motor running at the value set in terms of a % of the value set in the High-Speed parameter (P8-06), then at the next stop command the value of the parameter will return to 0.0 automatically so that the test is not repeated, and normal operation is resumed.